Office closed 25 Dec, 26 Dec & 1 Jan 2026. Normal operations resume next working day. Happy Holidays

Brand
AS

Heart Internal Structures 3D Printed Anatomy Model [Pack of 1]

In stock
SKU
MP1715
MPC
MP1715
Brand
AS
Lead Time
Delivered within 3- 4weeks or Earlier
SKU
MP1715
£1,701.00 £1,417.50

3D printed cadaver substitute showing a human heart dissected to display the internal structures of the chambers.

This heart 3D printed model shows a human heart dissected to display the internal structures of the chambers.

The 3D Human Anatomy Series is the result of a collaboration between Monash University in Australia and German manufacturer Erler Zimmer. The 3D printed human anatomy models in this collection are highly accurate colour-augmented representations, designed to substitute the use of real human cadavers in anatomy education. Each model has been developed from radiographic data or cadaver specimins, providing a highly cost effective and ethical solution to meet the needs of medical, allied health and biological science educators.

At the base of the heart the termination of the superior vena cava is preserved entering the right atrium. Part of the inferior vena cava is also preserved on the inferior aspect of the right atrium; however, most of the vessel lumen and much of the anterior wall has been removed to expose the pectinate muscles of the right auricle and the fossa ovalis (which is nearly translucent in the 3D print). The anterior wall of the right ventricle has also been removed to expose the right atrioventricular valve and its three cusps (anterior, posterior, and septal), including the chordae tendineae connecting them to respective papillary muscles projecting from trabeculae carneae (including a septomarginal trabecula entering the anterior papillary muscle from the interventricular septum). The smooth wall of the conus arteriosus is also exposed leading to the pulmonary semilunar valve (left, right, and anterior cusps) at the base of the pulmonary trunk.

 

More Information
Additional Features

Preserved and encircling the right atrioventricular valve is the right coronary artery, ultimately passing to the posterior aspect and the origin of the posterior interventricular artery and atrioventricular nodal artery. On the posterior side of heart the terminations of the pulmonary veins are visible entering the opened left atrium. Just anterior to the depression of the fossa ovalis in the interatrial septum the left atrioventricular valve with its two cusps (anterior and posterior) is preserved, along with the associated chordae tendineae and papillary muscles in the ventricle. The walls of the opened left ventricle preserve well-developed trabeculae carneae.

At the apex of the ventricle the aortic semilunar valve (with left, right, and posterior cusps preserved) can be seen at the base of the sectioned aorta alongside the origin of both coronary arteries. The left coronary artery in this specimen is very short, giving rise almost immediately from its origin to the left anterior descending artery, the diagonal artery, the ramus intermedius, and the circumflex branch. The latter branch passes between the left atrium and ventricle adjacent to the opened coronary sinus leading to the right atrium. The left anterior descending branch penetrates the myocardium in this individual and travels through the tissue, only emerging superficially to become visible again near the apex.

 

Is on Sale No

AHP Medical supplies health professional , business & home users

* Debit/Credit Card Payments Accepted

* NHS or Company Purchase Order - email accounts@ahpmedicals.com

* Delivery to Private or Commercial Addresses

* Established 2001

Delivery

  • This product is usually dispatched via Royalmail, parcelforce, Dx and delivery should be within 2 to 4 working days.
  • £7.50 + VAT will be charged for all orders delivered to UK Mainland.
  • £15.00 + VAT will be charged to deliver to Scottish Highlands
  • £22.50 + VAT will be charged to deliver to Northern Ireland
  • If you would like 1 day delivery information on your medical supplies order, please call our Customer Care Team on 0207 378 6172 who will be able to give you further updates.

Read More here: Delivery Policy


Return

  • Non-Faulty Products: Notify us within 3 working days if unsatisfied. Return the product in original condition at your cost for a credit note.
  • Damaged Products: Report within 3 working days. We’ll collect and offer a refund or exchange.
  • Faulty Products: Inform us within 14 working days. We’ll collect and provide a refund or exchange.
  • Non-Returnable Items: Single-use instruments, sterile items, custom orders, cold chain products, autoclaves, pharmaceuticals, and similar items cannot be returned unless due to a picking error.

Read More here: Return Policy